1,076 research outputs found

    Learning by example : training users with high-quality query suggestions

    Get PDF
    The queries submitted by users to search engines often poorly describe their information needs and represent a potential bottleneck in the system. In this paper we investigate to what extent it is possible to aid users in learning how to formulate better queries by providing examples of high-quality queries interactively during a number of search sessions. By means of several controlled user studies we collect quantitative and qualitative evidence that shows: (1) study participants are able to identify and abstract qualities of queries that make them highly effective, (2) after seeing high-quality example queries participants are able to themselves create queries that are highly effective, and, (3) those queries look similar to expert queries as defined in the literature. We conclude by discussing what the findings mean in the context of the design of interactive search systems

    The Christmas Island Seamount Province, Indian Ocean: Origin of Intraplate Volcanism by Shallow Recycling of Continental Lithosphere?

    Get PDF
    The east-west-trending Christmas Island Seamount Province (CHRISP, 1800x600 km) in the northeastern Indian Ocean is elongated orthogonal to present-day plate motion, posing the question if a mantle plume formed this volcanic belt. Here we report the first age (Ar/Ar) and geochemical (Sr- Nd-Hf-Pb DS isotopic data) from the CHRISP seamount chain. A crude E-W age decrease from the Argo Basin (136 Ma), to the Eastern Wharton Basin (115-94 Ma) to the Vening-Meinesz seamounts (96-64 Ma) to the Cocos-Keeling seamounts (56-47 Ma) suggests spatial migration of melting. Christmas Island, however, yields much younger ages (44-4 Ma), inconsistent with an age progression. The isotopic compositions (e.g. 206Pb/204Pb = 17.3-19.3; 207Pb/204Pb = 15.49- 15.67; 143Nd/144Nd = 0.51220-0.51295; 176Hf/177Hf = 0.28246- 0.28319) range from enriched MORB (or “C”) to very enriched mantle (EM1) type compositions more typical of continental than oceanic volcanism. Lamproitic and kimberlitic rocks from western Australia, India and other continental areas, derived from metasomatized subcontinental lithospheric mantle, could serve as the EM1 type endmembers. The morphology, ages and chemical composition of the CHRISP, combined with plate tectonic reconstructions, cannot be easily explained within the framework of the mantle plume hypotheses. We therefore propose that the seamounts are derived through the recycling of continental lithosphere (mantle ± lower crust) delaminated during the breakup of Gondwana and brought to the surface at the former spreading centers separating Argoland (western Burma), Greater India and Australia

    A Textured Silicon Calorimetric Light Detector

    Full text link
    We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption is compatible with the increase in surface area. For the geometrically thin detectors studied, energy resolution from athermal phonons, dominated by position dependence, is proportional to the surface-to-volume ratio. With the CaWO4 scintillating crystal used as light source, the time constants of the calorimeter should be adapted to the relatively slow light-emission times.Comment: Submitted to Journal of Applied Physic

    The Μ\nu-cleus experiment: A gram-scale fiducial-volume cryogenic detector for the first detection of coherent neutrino-nucleus scattering

    Full text link
    We discuss a small-scale experiment, called Îœ\nu-cleus, for the first detection of coherent neutrino-nucleus scattering by probing nuclear-recoil energies down to the 10 eV-regime. The detector consists of low-threshold CaWO4_4 and Al2_2O3_3 calorimeter arrays with a total mass of about 10 g and several cryogenic veto detectors operated at millikelvin temperatures. Realizing a fiducial volume and a multi-element target, the detector enables active discrimination of Îł\gamma, neutron and surface backgrounds. A first prototype Al2_2O3_3 device, operated above ground in a setup without shielding, has achieved an energy threshold of ∌20{\sim20} eV and further improvements are in reach. A sensitivity study for the detection of coherent neutrino scattering at nuclear power plants shows a unique discovery potential (5σ\sigma) within a measuring time of â‰Č2{\lesssim2} weeks. Furthermore, a site at a thermal research reactor and the use of a radioactive neutrino source are investigated. With this technology, real-time monitoring of nuclear power plants is feasible.Comment: 14 pages, 19 figure

    The CRESST Experiment: Recent Results and Prospects

    Get PDF
    The CRESST experiment seeks hypothetical WIMP particles that could account for the bulk of dark matter in the Universe. The detectors are cryogenic calorimeters in which WIMPs would scatter elastically on nuclei, releasing phonons. The first phase of the experiment has successfully deployed several 262 g sapphire devices in the Gran Sasso underground laboratories. A main source of background has been identified as microscopic mechanical fracturing of the crystals, and has been eliminated, improving the background rate by up to three orders of magnitude at low energies, leaving a rate close to one count per day per kg and per keV above 10 keV recoil energy. This background now appears to be dominated by radioactivity, and future CRESST scintillating calorimeters which simultaneously measure light and phonons will allow rejection of a great part of it.Comment: To appear in the proceedings of the CAPP2000 Conference, Verbier, Switzerland, July, 2000 (eds J. Garcia-Bellido, R. Durrer, and M. Shaposhnikov
    • 

    corecore